Interactive guide

Lighting an office to AS/NZS 1680

How designers work out how many lights an office needs, and why. Seven short steps, each with a plan of the same room that you can move, built on the same calculation as our light estimator.

Scroll to start

Step 1

What the standard asks for

AS/NZS 1680 sets how much light a task needs, measured as maintained illuminance on the work plane. For a desk that is a horizontal plane 720 mm above the floor, so that is where every plan on this page is measured, not the floor.

The target depends on what the room is used for. We use 320 lx for an office and for a meeting room, and 160 lx for a reception. Switch the room type to see the same fitting laid out for each.

The layout is suggested by the same engine as the light estimator: the smallest even grid that reaches the target with acceptable evenness.

5.0 m long4.0 m wide
Target
320 lx (Office)
Maintained average at desk height
343 lx
Fittings
9 fittings, 3 × 3, about 1.7 m by 1.3 m apart
Plan of a 5.0 m by 4.0 m room, lux at desk height (720 mm). Each ring is a fitting.
  • <50
  • 50–100
  • 100–150
  • 150–200
  • 200–300
  • 300–400
  • 400–500
  • 500–750
  • 750+

Step 2

Maintenance factor: why you design brighter on day one

The target is a maintained value: what the room must still deliver after dust builds up on the fitting and the LEDs age. So a new installation has to be brighter than the target to stay above it.

We use a maintenance factor of 0.8, which means the room is designed to give about 25% more light on day one than the target. Drag the slider, or press Replay, to watch the plan fade from new to maintained.

The estimator quotes the maintained figure, so the number you see there is already the one to compare with the target.

5.0 m long4.0 m wide
Now showing
343 lx
Day one (new)
429 lx
Maintained (what the standard asks for)
343 lx
The same room and fittings. Day one is the engine's maintained figure divided by its 0.8 maintenance factor, about 25% more light.
  • <50
  • 50–100
  • 100–150
  • 150–200
  • 200–300
  • 300–400
  • 400–500
  • 500–750
  • 750+

Step 3

Uniformity: the average is not enough

An average can hide dark patches. Uniformity (U0) is the lowest lux on the work plane divided by the average, so 1.0 would be perfectly even and a low number means a dark spot somewhere a person will sit.

Here is one room with the same number of fittings. Pull them together and the middle gets bright while the edges go dim. Spread them out and U0 climbs. The plan recalculates as you move the slider, and the two ends are listed under it.

Our estimator aims for a U0 of 0.4 or more, and checks it before suggesting a layout.

5.0 m long4.0 m wide
Uniformity U0 (lowest ÷ average)
0.60
Average
343 lx
Darkest spot
206 lx

Bunched: U0 0.31, darkest spot 143 lx. Even grid: U0 0.60, darkest spot 206 lx.

The same 9 fittings in the same room. Drag the slider to move them.
  • <50
  • 50–100
  • 100–150
  • 150–200
  • 200–300
  • 300–400
  • 400–500
  • 500–750
  • 750+

Step 4

Spacing and mounting height

Each fitting lights a pool on the desk. How far apart the pools sit compared with how high the fittings are decides whether they merge into an even blanket or leave gaps.

Raise the ceiling and every pool widens and overlaps its neighbours, which evens the light out but also spreads it thinner, so the average falls. Lower it and the pools shrink toward separate spots. Change the number of fittings to move them closer or further apart.

A common rule of thumb is to keep the spacing within about 1.5 times the mounting height (ceiling height less the 720 mm desk). The estimator uses it, and so does this diagram.

5.0 m long4.0 m wide

Ceiling 2.7 m

Spacing ÷ mounting height
0.84 (1.7 m ÷ 2.0 m)
Average
343 lx (target 320 lx)
Uniformity U0
0.60
Dashed rings mark where each fitting's light has fallen to half of its value directly below.
  • <50
  • 50–100
  • 100–150
  • 150–200
  • 200–300
  • 300–400
  • 400–500
  • 500–750
  • 750+

Step 5

Beam angle

The beam angle is how wide a fitting spreads its light. A narrower beam, like the 60° option on Geber, puts more of its light straight down onto the desks. A wide beam, like the 90° on Bell, throws more of it out sideways, where some lands on the walls or is lost at the edges of the work area.

To compare fairly, both plans use the same room, the same fitting positions and the same lumens, so only the beam differs. Neither is better in every room: a wide beam covers more of the room from each fitting, while a narrow beam puts more of the same light on the desks.

60° beam (as on Geber)

Desk height, 720 mm
5.0 m long4.0 m wide
Average on the desks
439 lx
Light that lands on the desk plane in the room
74%
Uniformity U0
0.58

90° beam (as on Bell)

Desk height, 720 mm
5.0 m long4.0 m wide
Average on the desks
343 lx
Light that lands on the desk plane in the room
58%
Uniformity U0
0.60
Same room, same 9 positions and the same 1,350 lm per fitting, so only the beam angle differs.
  • <50
  • 50–100
  • 100–150
  • 150–200
  • 200–300
  • 300–400
  • 400–500
  • 500–750
  • 750+

Step 6

Glare

People in offices look at screens, so offices aim for low glare, rated as the Unified Glare Rating (UGR). A lower UGR is more comfortable.

One of the main things that helps is hiding the bare LED. A deep-recessed downlight keeps the light source up inside the fitting, so from across the room you see the recess wall rather than the LED. Move the slider to see how depth changes what a person looking from the side can see.

These Tunable fittings list a UGR rating in their specifications, lowest first:

UGR values are as published on each product page. Check the rating of the exact variant you specify.

Recess 45 mm (illustrative)
Recess depth
45 mm (illustrative)
Bare LED visible within
55° of straight below
Looking from 60° off the vertical
You see only the recess wall
An illustration of the geometry, not a measurement of any Tunable fitting: the deeper the recess, the less of the bare LED you can see from the side.

Step 7

Controls: dimming back to target

Because a design always lands a little above the target, controls bring it back. In an office, each room is its own DALI group. At commissioning, an installer sets the group's output so the room measures just at the target, rather than leaving every fitting at full power. Press Commission to watch that happen, and try the other room types.

The watts shown assume the load follows the dim level. That is an approximation, but it shows the direction: lights that are not needed are lights you do not pay to run.

A DALI-2 system can also add:

  • Presence sensors that switch or dim a room when nobody is in it.
  • Daylight sensors that lower the light near windows when the sun is doing the work.
  • Scene keypads and dimmers so people can set the room for a meeting or a presentation.
  • Apps, gateways and a BMS interface to adjust and monitor the building.

Our team handles on-site commissioning, and after-service site monitoring and support is available under a maintenance contract. How DALI-2 works is explained step by step in DALI-2 explained.

Wired or wireless: DALI-2, DMX, Casambi, Syncromesh, from a single sensor to a full control system with BMS interface and cloud monitoring, backed by maintenance contracts.

5.0 m long4.0 m wide
At 100%
343 lx, 135 W
Commissioned to 320 lx
93% output, about 126 W
Now showing
93%, 320 lx, about 126 W
Dimming back to the target at commissioning. Watts assume the load follows the dim level, which is an approximation.
  • <50
  • 50–100
  • 100–150
  • 150–200
  • 200–300
  • 300–400
  • 400–500
  • 500–750
  • 750+

Where next

This guide is an estimate built on a simplified model: point sources, a flat allowance for reflected light and a 0.8 maintenance factor. A real design uses each fitting's measured photometry, your room's surfaces and furniture, and the standard itself.

Lighting design

We'll light yours.

Send us your plans and we'll calculate the light, design the controls and render the room.